create dynamic impulse trigger with data page |
fix types, examples go on dymamic impulses page |
||
(4 intermediate revisions by the same user not shown) | |||
Line 4: | Line 4: | ||
|Inputs= | |Inputs= | ||
[ | [ | ||
{"Name":"*", "Type":" | {"Name":"*", "Type":"Call"}, | ||
{"Name":"Tag", "Type":"String"}, | {"Name":"Tag", "Type":"String"}, | ||
{"Name":"TargetHierarchy", "Type":"Slot"}, | {"Name":"TargetHierarchy", "Type":"Slot"}, | ||
Line 21: | Line 21: | ||
== Inputs == | == Inputs == | ||
=== * (Call) === | === * ([[Impulses|Call]]) === | ||
Trigger the input slot TargetHierarchy ([[Slot|Slot]]) with the given | Trigger the input slot TargetHierarchy ([[Slot|Slot]]) with the given Tag ([[Type:String|String]]) and Value (Generic). | ||
=== Tag ([[Type:String|String]]) === | |||
The tag of the Dynamic Impulse that should be sent after calling * ([[Impulses|Call]]). | |||
=== TargetHierarchy ([[Slot|Slot]]) === | === TargetHierarchy ([[Slot|Slot]]) === | ||
Line 39: | Line 43: | ||
== Outputs == | == Outputs == | ||
=== Next (Continuation) === | === Next ([[Impulses|Continuation]]) === | ||
Code to run after all the code ran by the eligible dynamic impulse receivers is done running, excluding a-syncs created by the receivers. | Code to run after all the code ran by the eligible dynamic impulse receivers is done running, excluding a-syncs created by the receivers. | ||
=== TriggeredCount === | === TriggeredCount ([[Types:Int|Int]])=== | ||
Number of Dynamic Impulse Receivers that were eligible and got triggered. | Number of Dynamic Impulse Receivers that were eligible and got triggered. | ||
[[Category:ProtoFlux:Flow]] | [[Category:ProtoFlux:Flow]] |
Latest revision as of 19:54, 9 February 2024
Dynamic Impulse Trigger With Data
Flow
Since Dynamic Impulses can be a complex topic, the usage of this node is part of the Dynamic Impulses page.
Inputs
* (Call)
Trigger the input slot TargetHierarchy (Slot) with the given Tag (String) and Value (Generic).
Tag (String)
The tag of the Dynamic Impulse that should be sent after calling * (Call).
TargetHierarchy (Slot)
The Slot under which to trigger eligible Dynamic Impulse Recievers.
ExcludeDisabled (bool)
Decides if this node should or should not activate eligible dynamic receivers that are under disabled hierarchy.
Value (Generic)
Value to send with this impulse.
Outputs
Next (Continuation)
Code to run after all the code ran by the eligible dynamic impulse receivers is done running, excluding a-syncs created by the receivers.
TriggeredCount (Int)
Number of Dynamic Impulse Receivers that were eligible and got triggered.